JX RO3-T
| Availability: | |
|---|---|
JX Series high temperature membranes are designed for reliable performance in high temperature reverse osmosis applications.Membrane Chemistry: Polyamide; Structure: Sanitary grade mesh outer appearance; Stabilized Salt Rejection:99.0%; Minimum Salt Rejection:98.0%.
Test Condition Description:
Salt rejection test conditions:2,000 ppm NaCl,15.5 bar(25℃),15%recovery, pH 8.0,operated for 30 minutes.
Permeate flow test conditions:Pure water under above conditions. Single element permeate flow may vary within ±15%.
Core Advantages:
1. Continuous operating temperature:5~65℃@25bar, much higher than standard RO’s 5~45℃. No pre-cooling heat exchanger required for hot feed water to reduce CAPEX and OPEX;
2. CIP cleaning at 40~50℃ enables efficient high-temperature chemical circulation cleaning to thoroughly remove scaling & colloidal fouling and extend service life;
3. Wide pH tolerance: continuous service pH3~10, cleaning pH2~12; max pressure drop per element 0.7bar for stable long-term operation;
4. Four full-size options (1812/2540/4040/8040) covering lab small pure water equipment to large-scale industrial RO systems.
content is empty!