Reverse osmosis is the process of applying a pressure greater than the osmotic pressure of the solution on the side of the concentrated solution, forcing the water molecules to enter the dilute solution through the semi-permeable membrane in the reverse direction (opposite to the direction of natural osmosis). The semipermeable membrane flows to dilute solutions, while most of the solutes (dissolved solids) cannot pass through the membrane and are trapped. What is reverse osmosis? The two solutions with concentration are separated by a semi-permeable membrane (Membrane). After a certain period of time, the solution with lower concentration will move to the side with higher concentration. The difference in water level that occurs is called 'osmotic pressure', and the reverse osmosis pressure is The osmotic pressure, reverse loading, is a water purification method in which only water molecules can pass through a semipermeable membrane. |
Reverse osmosis is the process of applying a pressure greater than the osmotic pressure of the solution on the side of the concentrated solution, forcing the water molecules to enter the dilute solution through the semi-permeable membrane in the reverse direction (opposite to the direction of natural osmosis). The semipermeable membrane flows to dilute solutions, while most of the solutes (dissolved solids) cannot pass through the membrane and are trapped. What is reverse osmosis? The two solutions with concentration are separated by a semi-permeable membrane (Membrane). After a certain period of time, the solution with lower concentration will move to the side with higher concentration. The difference in water level that occurs is called 'osmotic pressure', and the reverse osmosis pressure is The osmotic pressure, reverse loading, is a water purification method in which only water molecules can pass through a semipermeable membrane. |
LP Series
The target water source is low to medium salinity surface water/groundwater, etc., it can achieve the same high water flux and high salt rejection rate as conventional low pressure membranes under extremely low operating pressure conditions. Its operating pressure is about 2/3 of the conventional low-pressure membrane operating pressure, and the desalination rate reaches 99.5%. Because the operating pressure is low and the salt rejection rate is high, the economic benefits are obvious. LP is suitable for desalination treatment of drinking water sources such as surface water/groundwater/tap water/municipal water with a salt content below 2000ppm. Main uses: drinking water, purified water production, boiler feed water, food processing and pharmaceutical production water. |
LP 4" MEMBRANE ELEMENTS
Model | JXLP11-4040 | JXLP12-4040 | JXLP13-4040 |
Effective membrane area ft2(m2) | 85(7.9) | 85(7.9) | 85(7.9) |
Operating pressure psi(MPa) | 150(1.03) | ||
Average yield GPD(m3/d) | 2700(910.2) | 2400(9.1) | 1900(7.2) |
Salt rejection (%) | 98 (min97.5) | 99(min 98.5) | 99.4(min 99.0) |
Recovery rate (%) | 15 | ||
Max. operating pressure psi(MPa) | 600(4.14)600(4.14) | ||
Max. inflow temperature(°C) | 45 | ||
Max. inflow SDI | 5 | ||
Max. water flow GPM(m3/h) | 16(3.6) | ||
Free chlorine concentration | <0.1 | ||
Continuous running water pH range | 3-10 | ||
Chemical cleaning water pH range | 2-11 | ||
Max. single membrane element pressure drop | 15 (0.1) |
LP 8" MEMBRANE ELEMENTS
Model | JXLP21-8040 | JXLP22-8040 | JXLP23-8040 | JXLP24-8040 |
Effective membrane area ft2(m2) | 365(33.9) | 400(37.0) | 400(37.0) | 400(37.0) |
Operating pressure psi(MPa) | 150(1.05) | |||
Average yield GPD(m3/d) | 11,000(41.6) | 13,200(49.9) | 12,100(45.7) | 10,500(38.7) |
Salt rejection (%) | 99(MIN98.5) | 98(min97.5) | 99(min98.5) | 99.5(min99.0) |
Recovery rate (%) | 15 | |||
Max. operating pressure psi(MPa) | 600(4.2) | |||
Max. inflow temperature(°C) | 45 | |||
Max. inflow SDI | 5 | |||
Max. water flow GPM(m3/h) | 75(17) | |||
Free chlorine concentration | <0.1 | |||
Continuous running water pH range | 3-10 | |||
Chemical cleaning water pH range | 2-11 | |||
Max. single membrane element pressure drop | 15 (0.1) |
FR Series
FR series of fouling resistant aromatic polyamide composite membrane element is developed by JX for complex water quality. FR series element with special membrane preparation process, it improved the hydrophilicity, charge characteristic and roughness, can effectively reduce the breeding of bio-fouling and adsorption of pollutants in the membrane surface. The element is applied a special 34 mil spacer design, which effectively reduced fouling and pressure drop, with more durable on cleaning can extent the service life. FR series of fouling resistant membranes normally suitable for treatment of complex water source with TDS less than 10000 ppm. It is mainly used for purification of surface water, mining waste water, municipal reclaimed water, industrial waste water, RO brackish water. |
Module | Active Membrane Area | Average Permeate | Stable rejection | Min rejection | |
ft2(m2) | GPD(m³/d) | Rate(%) | Rate(%) | ||
JXFR-8040 | 400(37.2) | 10500(39.7) | 99.7 | 99.6 | |
Test conditions: | |||||
Testing pressure | 225Psi(1.55Mpa) | ||||
Testing solution temperature | 25℃ | ||||
Concentration of testing solution | 2000ppm | ||||
pH value of testing solution | 7 | ||||
Recovery rate of Single element | 15% | ||||
Feed spacer | 34mil(0.86mm) | ||||
Operation limits & conditions: | |||||
Max. Working Pressure | 600psi(4.14Mpa) | ||||
Max. Temperature of Feed water | 45℃ | ||||
Max. Volume of Feed water | 75gpm(17 m3/h) | ||||
Max. Feed water SDI15 | 5.0 | ||||
Max. Feed water Turbidity | 1.0NTU | ||||
pH Range of Feed water during Continuous Operation | 2~11 | ||||
pH Range of Feed water during Chemical Cleaning | 1~13 | ||||
Residual Chlorine Concentration of Feed Water | <0.1ppm | ||||
Max. Pressure Drop of Single Membrane Element | 15psi(0.1Mpa) | ||||
Max. Pressure Drop of Single Pressure Vessel with Six elements | 50psi(0.34Mpa) |
SW Series
SW is suitable for reverse osmosis membrane elements installed at sea and on land. It has the characteristics of high pressure resistance (up to 6.9Mpa), low operating cost, good desalination performance, and stable desalination effect. Drinking water from seawater can be guaranteed under high recovery conditions. SW series membrane elements are suitable for various industrial water treatment such as seawater desalination, high-concentration brackish water desalination, power plant boiler make-up water, etc., and can also be used in various fields such as concentration and recovery of wastewater reuse. Main uses: seawater desalination, high concentration brackish water desalination, industrial water treatment, waste water reuse. |
Module | Active Membrane Area | Average Permeate | Stable rejection | Min rejection | B rejection |
ft2(m2) | GPD(m³/d) | Rate(%) | Rate(%) | Rate(%) | |
JXSW-8040 | 400(37.2) | 7500(39.7) | 99.85 | 99.7 | 93 |
Test conditions: | |||||
Testing pressure | 800Psi(5.5Mpa) | ||||
Testing solution temperature | 25℃ | ||||
Concentration of testing solution | 32000ppm Nacl,5ppm B. | ||||
pH value of testing solution | 8.0 | ||||
Recovery rate of Single element | 8% | ||||
Feed spacer | 34mil(0.86mm) | ||||
Operation limits & conditions: | |||||
Max. Working Pressure | 1200psi(8.27Mpa) | ||||
Max. Temperature of Feed water | 45℃ | ||||
Max. Volume of Feed water | 75gpm(17 m3/h) | ||||
Max. Feed water SDI15 | 5.0 | ||||
Max. Feed water Turbidity | 1.0NTU | ||||
pH Range of Feed water during Continuous Operation | 2~11 | ||||
pH Range of Feed water during Chemical Cleaning | 1~13 | ||||
Residual Chlorine Concentration of Feed Water | <0.1ppm | ||||
Max. Pressure Drop of Single Membrane Element | 15psi(0.1Mpa) | ||||
Max. Pressure Drop of Single Pressure Vessel with Six elements | 50psi(0.34Mpa) |
LP Series
The target water source is low to medium salinity surface water/groundwater, etc., it can achieve the same high water flux and high salt rejection rate as conventional low pressure membranes under extremely low operating pressure conditions. Its operating pressure is about 2/3 of the conventional low-pressure membrane operating pressure, and the desalination rate reaches 99.5%. Because the operating pressure is low and the salt rejection rate is high, the economic benefits are obvious. LP is suitable for desalination treatment of drinking water sources such as surface water/groundwater/tap water/municipal water with a salt content below 2000ppm. Main uses: drinking water, purified water production, boiler feed water, food processing and pharmaceutical production water. |
LP 4" MEMBRANE ELEMENTS
Model | JXLP11-4040 | JXLP12-4040 | JXLP13-4040 |
Effective membrane area ft2(m2) | 85(7.9) | 85(7.9) | 85(7.9) |
Operating pressure psi(MPa) | 150(1.03) | ||
Average yield GPD(m3/d) | 2700(910.2) | 2400(9.1) | 1900(7.2) |
Salt rejection (%) | 98 (min97.5) | 99(min 98.5) | 99.4(min 99.0) |
Recovery rate (%) | 15 | ||
Max. operating pressure psi(MPa) | 600(4.14)600(4.14) | ||
Max. inflow temperature(°C) | 45 | ||
Max. inflow SDI | 5 | ||
Max. water flow GPM(m3/h) | 16(3.6) | ||
Free chlorine concentration | <0.1 | ||
Continuous running water pH range | 3-10 | ||
Chemical cleaning water pH range | 2-11 | ||
Max. single membrane element pressure drop | 15 (0.1) |
LP 8" MEMBRANE ELEMENTS
Model | JXLP21-8040 | JXLP22-8040 | JXLP23-8040 | JXLP24-8040 |
Effective membrane area ft2(m2) | 365(33.9) | 400(37.0) | 400(37.0) | 400(37.0) |
Operating pressure psi(MPa) | 150(1.05) | |||
Average yield GPD(m3/d) | 11,000(41.6) | 13,200(49.9) | 12,100(45.7) | 10,500(38.7) |
Salt rejection (%) | 99(MIN98.5) | 98(min97.5) | 99(min98.5) | 99.5(min99.0) |
Recovery rate (%) | 15 | |||
Max. operating pressure psi(MPa) | 600(4.2) | |||
Max. inflow temperature(°C) | 45 | |||
Max. inflow SDI | 5 | |||
Max. water flow GPM(m3/h) | 75(17) | |||
Free chlorine concentration | <0.1 | |||
Continuous running water pH range | 3-10 | |||
Chemical cleaning water pH range | 2-11 | |||
Max. single membrane element pressure drop | 15 (0.1) |
FR Series
FR series of fouling resistant aromatic polyamide composite membrane element is developed by JX for complex water quality. FR series element with special membrane preparation process, it improved the hydrophilicity, charge characteristic and roughness, can effectively reduce the breeding of bio-fouling and adsorption of pollutants in the membrane surface. The element is applied a special 34 mil spacer design, which effectively reduced fouling and pressure drop, with more durable on cleaning can extent the service life. FR series of fouling resistant membranes normally suitable for treatment of complex water source with TDS less than 10000 ppm. It is mainly used for purification of surface water, mining waste water, municipal reclaimed water, industrial waste water, RO brackish water. |
Module | Active Membrane Area | Average Permeate | Stable rejection | Min rejection | |
ft2(m2) | GPD(m³/d) | Rate(%) | Rate(%) | ||
JXFR-8040 | 400(37.2) | 10500(39.7) | 99.7 | 99.6 | |
Test conditions: | |||||
Testing pressure | 225Psi(1.55Mpa) | ||||
Testing solution temperature | 25℃ | ||||
Concentration of testing solution | 2000ppm | ||||
pH value of testing solution | 7 | ||||
Recovery rate of Single element | 15% | ||||
Feed spacer | 34mil(0.86mm) | ||||
Operation limits & conditions: | |||||
Max. Working Pressure | 600psi(4.14Mpa) | ||||
Max. Temperature of Feed water | 45℃ | ||||
Max. Volume of Feed water | 75gpm(17 m3/h) | ||||
Max. Feed water SDI15 | 5.0 | ||||
Max. Feed water Turbidity | 1.0NTU | ||||
pH Range of Feed water during Continuous Operation | 2~11 | ||||
pH Range of Feed water during Chemical Cleaning | 1~13 | ||||
Residual Chlorine Concentration of Feed Water | <0.1ppm | ||||
Max. Pressure Drop of Single Membrane Element | 15psi(0.1Mpa) | ||||
Max. Pressure Drop of Single Pressure Vessel with Six elements | 50psi(0.34Mpa) |
SW Series
SW is suitable for reverse osmosis membrane elements installed at sea and on land. It has the characteristics of high pressure resistance (up to 6.9Mpa), low operating cost, good desalination performance, and stable desalination effect. Drinking water from seawater can be guaranteed under high recovery conditions. SW series membrane elements are suitable for various industrial water treatment such as seawater desalination, high-concentration brackish water desalination, power plant boiler make-up water, etc., and can also be used in various fields such as concentration and recovery of wastewater reuse. Main uses: seawater desalination, high concentration brackish water desalination, industrial water treatment, waste water reuse. |
Module | Active Membrane Area | Average Permeate | Stable rejection | Min rejection | B rejection |
ft2(m2) | GPD(m³/d) | Rate(%) | Rate(%) | Rate(%) | |
JXSW-8040 | 400(37.2) | 7500(39.7) | 99.85 | 99.7 | 93 |
Test conditions: | |||||
Testing pressure | 800Psi(5.5Mpa) | ||||
Testing solution temperature | 25℃ | ||||
Concentration of testing solution | 32000ppm Nacl,5ppm B. | ||||
pH value of testing solution | 8.0 | ||||
Recovery rate of Single element | 8% | ||||
Feed spacer | 34mil(0.86mm) | ||||
Operation limits & conditions: | |||||
Max. Working Pressure | 1200psi(8.27Mpa) | ||||
Max. Temperature of Feed water | 45℃ | ||||
Max. Volume of Feed water | 75gpm(17 m3/h) | ||||
Max. Feed water SDI15 | 5.0 | ||||
Max. Feed water Turbidity | 1.0NTU | ||||
pH Range of Feed water during Continuous Operation | 2~11 | ||||
pH Range of Feed water during Chemical Cleaning | 1~13 | ||||
Residual Chlorine Concentration of Feed Water | <0.1ppm | ||||
Max. Pressure Drop of Single Membrane Element | 15psi(0.1Mpa) | ||||
Max. Pressure Drop of Single Pressure Vessel with Six elements | 50psi(0.34Mpa) |
Nanjing Junxin Environmental Technology CO.,Ltd was found in 2014. JX Purification is a professional manufacture which engaged in water purification, medical purification, air purification, other environmental products such as solar panels, metal insulation board, PTFE films and so on. JX Purification boasts the leading productivity in the same sector, with the total area of 6 factories hitting 5000sqm. We have more than hundreds production lines and thousands equipments. With more than thousands stuff. 20% of the stuff is the R&D talents. |
Different situations will use different purification system solutions. We can provide Ro membrane & Modules(LP/ULP Series, FR Series, BW/SW Series), Ro industrial wastewater treatment system,Small domestic Ro reverse osmosis system, PVDF MBR membrane & Modules, PTFE MBR membrane & Modules, MBR flat sheet membrane & Modules, Ceramic flat sheet membrane & Modules, UF membrane & Modules, Tubular UF membrane modules, Wastewater treatment system, etc. and use different combinations to provide the most valuable services.
FAQ |
Q: | Are you a trading company or manufacturer? |
A: | We are factory with abundant production experience since 2007,and we set our own trade company in 2014 for opening overseas market. |
Q: | What's your company MOQ? |
A: | MOQ is 1 set. Favorable price will be sent base on your large order. |
Q: | Will you provide corresponding documents for Installation/Debugging |
A: | Yes, Technical Data Sheet/ Flowchart of Equipment/ Instruction (Manual) etc. will be provided after products delivery. |
Q: | How do you guarantee your quality ? |
A: | Our workers and technical employees are with many years experiences to ensure the products are good. After production finished,check will be made by quality inspector. Test of equipment also will be made before delivery. |
Nanjing Junxin Environmental Technology CO.,Ltd was found in 2014. JX Purification is a professional manufacture which engaged in water purification, medical purification, air purification, other environmental products such as solar panels, metal insulation board, PTFE films and so on. JX Purification boasts the leading productivity in the same sector, with the total area of 6 factories hitting 5000sqm. We have more than hundreds production lines and thousands equipments. With more than thousands stuff. 20% of the stuff is the R&D talents. |
Different situations will use different purification system solutions. We can provide Ro membrane & Modules(LP/ULP Series, FR Series, BW/SW Series), Ro industrial wastewater treatment system,Small domestic Ro reverse osmosis system, PVDF MBR membrane & Modules, PTFE MBR membrane & Modules, MBR flat sheet membrane & Modules, Ceramic flat sheet membrane & Modules, UF membrane & Modules, Tubular UF membrane modules, Wastewater treatment system, etc. and use different combinations to provide the most valuable services.
FAQ |
Q: | Are you a trading company or manufacturer? |
A: | We are factory with abundant production experience since 2007,and we set our own trade company in 2014 for opening overseas market. |
Q: | What's your company MOQ? |
A: | MOQ is 1 set. Favorable price will be sent base on your large order. |
Q: | Will you provide corresponding documents for Installation/Debugging |
A: | Yes, Technical Data Sheet/ Flowchart of Equipment/ Instruction (Manual) etc. will be provided after products delivery. |
Q: | How do you guarantee your quality ? |
A: | Our workers and technical employees are with many years experiences to ensure the products are good. After production finished,check will be made by quality inspector. Test of equipment also will be made before delivery. |
Quality Assurance Policy |
Warranty period: 1-5 years
Our company provides a warranty period of 1- 5 years. During this period, our company is responsible for video or telephone maintenance and debugging due to product quality problems under normal operating conditions.
After the membrane modules are delivered for use, our company will provide tracking services for the products. Our company will supply professional service by video or telephone for return visits every year. If there is a quality problem with the membrane module, we guarantee that after receiving any form of notification from the user, we will respond within 24 hours, and complete the repair or replacement within 48 hours to completely solve the failure.
If the product is damaged due to improper use by customers, in line with the principle of solving the problem for the customer to the greatest extent, after consultation between the two parties, the maintenance task can be completed in a timely and effective manner.
During the on-site service, the after-sales service personnel shall organize and implement the plan confirmed by both parties. After the service is completed, the buyer shall be asked to check and approve the project, and sign opinions on the "After-sales Service Contact Sheet". The specific requirements and improvement suggestions of our company's product quality and service quality.
After Sales Service |
Shortage of goods
1.The number of goods will be confirmed before shipping to make sure there is no shortage. If there is any shortage happens, we will first discuss with clients before shipping.
2.lf ok, then payment will be reduced and boxes will be sent
3.lf not ok, reorder from sales department will be place to the workshop and finish the production soonest.
Damage of goods
We can guarantee the goods in good condition after our QC. But if there is any damage happened during transport, we can deliver the damage parts in next shipment.
lf the goods are damaged a lot, we will discuss it with the clients to figure out the reason and make amends.
Problem of goods
lf there are some problems of the goods, we will provide the solution and keep following up.
Online Customer Service |
How to contact us? We will provide you with after-sales service support within 24 hours. If you have any questions, you can consult our email or telephone. Tel/whatsapp: 008613182800856 Fax: 008618061698374 Phone: 008618061698374 |
Quality Assurance Policy |
Warranty period: 1-5 years
Our company provides a warranty period of 1- 5 years. During this period, our company is responsible for video or telephone maintenance and debugging due to product quality problems under normal operating conditions.
After the membrane modules are delivered for use, our company will provide tracking services for the products. Our company will supply professional service by video or telephone for return visits every year. If there is a quality problem with the membrane module, we guarantee that after receiving any form of notification from the user, we will respond within 24 hours, and complete the repair or replacement within 48 hours to completely solve the failure.
If the product is damaged due to improper use by customers, in line with the principle of solving the problem for the customer to the greatest extent, after consultation between the two parties, the maintenance task can be completed in a timely and effective manner.
During the on-site service, the after-sales service personnel shall organize and implement the plan confirmed by both parties. After the service is completed, the buyer shall be asked to check and approve the project, and sign opinions on the "After-sales Service Contact Sheet". The specific requirements and improvement suggestions of our company's product quality and service quality.
After Sales Service |
Shortage of goods
1.The number of goods will be confirmed before shipping to make sure there is no shortage. If there is any shortage happens, we will first discuss with clients before shipping.
2.lf ok, then payment will be reduced and boxes will be sent
3.lf not ok, reorder from sales department will be place to the workshop and finish the production soonest.
Damage of goods
We can guarantee the goods in good condition after our QC. But if there is any damage happened during transport, we can deliver the damage parts in next shipment.
lf the goods are damaged a lot, we will discuss it with the clients to figure out the reason and make amends.
Problem of goods
lf there are some problems of the goods, we will provide the solution and keep following up.
Online Customer Service |
How to contact us? We will provide you with after-sales service support within 24 hours. If you have any questions, you can consult our email or telephone. Tel/whatsapp: 008613182800856 Fax: 008618061698374 Phone: 008618061698374 |